Maintenance of Radiology Printing Machines: Nothing is free from the possibility of malfunctions, and in the field of medical Radiology Printing Machines, sometimes the machines are exposed to some malfunctions, some of which are easy to deal with without the need of a maintenance engineer, and others in which you need to consult the maintenance engineer by phone, and others that require the presence of the maintenance engineer To the factory headquarters to solve the malfunction and maintain the machine.
Ricoh MP C2800 medical radiography machine is one of the cheapest medical radiology printing machines and the most widely used model in radiology laboratories and centers.
Al-Ansar guaranteed the maintenance of Radiology Printing Machines with original spare parts
This is in the machine like others need maintenance and technical support from time to time, and in this article we review the most common faults of this machine within the radiology laboratories.
Of course, some of the following faults mentioned may be found in other models and brands, and the cause of the malfunction in each of them is not the same.
This indicates that the maintenance of medicalRadiology Printing Machines requires specialized maintenance centers and a great deal of experience and skill.
The most common malfunctions of the Ricoh MP C2800
• Crammed into the wash and back
• The appearance of a floor on the paper
• A blue line appears above the photocopy or print document
We will talk about these faults during the following lines:
Crammed into the wash and back
Sometimes some radiology centers resort to double-sided printing with weights in excess of 150 grams, which results in a duplex jam.
Because by locating the malfunction, the Radiology Printing Machines are serviced, and a problem has occurred in the duplex of the Ricoh MP C2800, which has several possibilities:
-
The firstborn of clouds
The duplex group's pulley is for drawing the paper and transferring it to the normal path inside the machine, but the accumulation of inks and dust on it prevents it from performing its job.
This issue is solved by thoroughly cleaning the drawing pulley or changing it if it is damaged.
-
Sensors
The accumulation of dust on the optical sensors obscures the light from them, causing the paper line inside the machine to be broken and its cycle not complete.And for maintenance of radiation printing machines suffering from this problem, it is to clean the sensors well, and if one of them is damaged it will be changed.
-
Duplex fork
It is one of the parts of the medical radiation machine responsible for changing the path of the paper to the other side to be printed on, sometimes it breaks or breaks, so the paper does not complete its path causing a duplex jam, and a solution is to change it.
-
Duplex group side door
Sometimes this door is not locked or sometimes the locker is broken or damaged, resulting in a duplex.
Therefore, it must be ensured that the side door is closed tightly, or the shutter or door is changed in case one of them is damaged.
blue line appears
A blue line appears above the documentThe appearance of glaucoma lines on the printed rays makes us put three possibilities on the maintenance of the radiation printing machines, and in this model they are as follows:
-
DRUM CODE:
And its main function is to clean the DRUM unit after each printing process, but sometimes it is subjected to corrosion or its shelf life ends, so it fails to perform its mission, and the solution here is to change it
Sometimes ink builds up on this blade, which affects its working properly and the solution here is to clean the blade well.
-
Crown color:
It is one of the very important parts of the ray printing machines, it works to charge the dram of blue color with electricity, but sometimes the electric current rises above the permissible level which leads to its being cut (stitched), which affects the way it works, and the solution changes the crown.
-
Drum color blue:
Sometimes the effect of the electric current extends to the group of drams responsible for the printing process, which also leads to their wrinkling, which affects the printing process, and the solution is to change the unit of the dram drama, in case it is deformed or spotted.Therefore, Al-Ansar Institution recommends to its office customers its clients that they must acquire a stabilizer in case of unstable electric current in order to preserve the machine and protect it from malfunctions.
The appearance of a floor on the paper
It is not possible to talk about the maintenance of Radiology Printing Machines without talking about the appearance of a floor in the paper, whether it is for a specific color of four (CMYK) or all of them or only two colors.
The reason for this is that there is a malfunction in the devilopure, and there are three possibilities for this:
• Reducing the amount of Dilflober inside the tank, and the solution is to supply the Tank with another amount of Dilflober.
• The presence of impurities inside the reservoir tank or ink conglomerate inside, and the solution is to clean it from impurities and lumpy ink and add a new development.
• Difficulty of tanker ship development or damage as a result of the end of life, and the solution is to change the whole group.
Maintenance of medical Radiology Printing Machines is not limited to these malfunctions only. There are many other malfunctions that we will talk about in future old_articles.